cm->emergency_stop will only be the value in the enumeration,
and can not be less than zero, it will get an exception value.
So replace it with the corresponding value.

Signed-off-by: Junlin Yang <yangjunlin@yulong.com>
---
drivers/power/supply/charger-manager.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/power/supply/charger-manager.c b/drivers/power/supply/charger-manager.c
index 6fcebe4..0d28741 100644
--- a/drivers/power/supply/charger-manager.c
+++ b/drivers/power/supply/charger-manager.c
@@ -723,9 +723,9 @@ static int charger_get_property(struct power_supply *psy,
val->intval = cm->battery_status;
break;
case POWER_SUPPLY_PROP_HEALTH:
- if (cm->emergency_stop > 0)
+ if (cm->emergency_stop == CM_BATT_OVERHEAT)
val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
- else if (cm->emergency_stop < 0)
+ else if (cm->emergency_stop == CM_BATT_COLD)
val->intval = POWER_SUPPLY_HEALTH_COLD;
else
val->intval = POWER_SUPPLY_HEALTH_GOOD;
--