lkml.org 
[lkml]   [2019]   [May]   [29]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH 1/2] scsi: libsas: only clear phy->in_shutdown after shutdown event done
From
Date

Jason,

> When the event queue is full of phy up and down events and reached the
> threshold, we will queue a shutdown-event, and set phy->in_shutdown so
> that we will not queue a shutdown-event again. But before the
> shutdown-event can be executed, every phy-down event will clear
> phy->in_shutdown and a new shutdown-event will be queued. The queue will
> be full of these shutdown-events.
>
> Fix this by only clear phy->in_shutdown in sas_phye_shutdown(), that is
> after the first shutdown-event has been executed.

Applied 1+2 to 5.2/scsi-fixes. Thanks!

--
Martin K. Petersen Oracle Linux Engineering

\
 
 \ /
  Last update: 2019-05-30 04:11    [W:0.103 / U:25.468 seconds]