SubjectRe: [PATCH v2 2/6] Documentation: DT: Add optional 'timeout-sec' property for sp805
From
Date


On 5/23/2018 3:29 PM, Guenter Roeck wrote:
> On Wed, May 23, 2018 at 01:32:03PM -0700, Ray Jui wrote:
>> Update the SP805 binding document to add optional 'timeout-sec'
>> devicetree property
>>
>> Signed-off-by: Ray Jui <ray.jui@broadcom.com>
>> Reviewed-by: Scott Branden <scott.branden@broadcom.com>
>> Reviewed-by: Guenter Roeck <linux@roeck-us.net>
>> ---
>> Documentation/devicetree/bindings/watchdog/arm,sp805.txt | 2 ++
>> 1 file changed, 2 insertions(+)
>>
>> diff --git a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
>> index de93a4d..9cd7470 100644
>> --- a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
>> +++ b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
>> @@ -18,6 +18,8 @@ Required properties:
>>
>> Optional properties:
>> - interrupts : Should specify WDT interrupt number.
>> +timeout-sec : Should specify default WDT timeout in seconds. If unset, the
>> + default timeout in the driver is 30 seconds
>
> That looks odd, with the changed indentation and the missing '-'
> in front of 'timeout-sec' >

My bad. Will fix this in v3. Thanks.

> Guenter
>

\
 
 \ /
  Last update: 2018-05-24 01:52    [W:0.048 / U:2.348 seconds]