SubjectRe: [PATCH v2 2/6] Documentation: DT: Add optional 'timeout-sec' property for sp805
On Wed, May 23, 2018 at 01:32:03PM -0700, Ray Jui wrote:
> Update the SP805 binding document to add optional 'timeout-sec'
> devicetree property
>
> Signed-off-by: Ray Jui <ray.jui@broadcom.com>
> Reviewed-by: Scott Branden <scott.branden@broadcom.com>
> Reviewed-by: Guenter Roeck <linux@roeck-us.net>
> ---
> Documentation/devicetree/bindings/watchdog/arm,sp805.txt | 2 ++
> 1 file changed, 2 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
> index de93a4d..9cd7470 100644
> --- a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
> +++ b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
> @@ -18,6 +18,8 @@ Required properties:
>
> Optional properties:
> - interrupts : Should specify WDT interrupt number.
> +timeout-sec : Should specify default WDT timeout in seconds. If unset, the
> + default timeout in the driver is 30 seconds

That looks odd, with the changed indentation and the missing '-'
in front of 'timeout-sec'.

Guenter

\
 
 \ /